Correction to: Scientific Reports https://doi.org/10.1038/s41598-021-02467-w, published online 29 November 2021
The original version of this Article contained errors in Figures 5 and 7 where the graphs in panels (a), (b) and (c) were incorrectly ordered. The original Figures 5 and 7 and accompanying legends appear below.
In addition, the original version of the Article contained errors in the Introduction and Results section.
In the Introduction,
“X-ray grating interferometry (XGI) based tensor tomography requires an additional angular degrees of freedom (in total three) and thus rather complex acquisition geometry16 because the linear grating do not provide directional scattering sensitivity, leading to a high acquisition overhead.”
now reads:
“X-ray grating interferometry (XGI) based tensor tomography requires additional angular degrees of freedom (in total three) and thus rather complex acquisition geometry16 because the linear grating do not provide directional scattering sensitivity, leading to a high acquisition overhead.”
In the Results section, under the subheading ‘Simulation study’,
“The same analysis has also been performed with only 100 projections (sparse sampling) with the results following the same trend regarding n and the accuracy metrics as reported fro 1000 projections.”
now reads:
“The same analysis has also been performed with only 100 projections (sparse sampling) with the results following the same trend regarding n and the accuracy metrics as reported from 1000 projections.”
The original Article has been corrected.
Author information
Authors and Affiliations
Corresponding authors
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Kim, J., Kagias, M., Marone, F. et al. Author Correction: Fast acquisition protocol for X-ray scattering tensor tomography. Sci Rep 12, 1571 (2022). https://doi.org/10.1038/s41598-022-05324-6
Published:
DOI: https://doi.org/10.1038/s41598-022-05324-6
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.